to move, Enter to open, Esc to close. Try 3.5.3, AC.L2-3.1.1, MFA or unmarked.

3.7.4Scan maintenance media in Rev. 3

Reworded: 03.07.04 Maintenance Tools.

Status as of 2026-09-08

Rev. 2 is what a contract requires today. DFARS 252.204-7012 and the CMMC rule at 32 CFR 170 point at NIST SP 800-171 Rev. 2, and a standing DoD class deviation keeps it there. NIST has published Rev. 3, but publishing a revision does not change an obligation. A move to Rev. 3 would arrive through the Department's reform process and formal rulemaking, a change to that deviation or an amendment to the rule, not through publication. The Department has published its organization-defined parameter values for Rev. 3 in preparation; that is groundwork, not adoption.

Side by side

Rev. 2 · in force 3.7.4 Media Inspection

Check media containing diagnostic and test programs for malicious code before the media are used in organizational systems.

Assessment objectives · 800-171A

  1. [a] media containing diagnostic and test programs are checked for malicious code before being used on the system

Rev. 3 · not adopted 03.07.04 Maintenance Tools

a. Approve, control, and monitor the use of system maintenance tools.

b. Check media with diagnostic and test programs for malicious code before it is used in the system.

c. Prevent the removal of system maintenance equipment containing CUI by verifying that there is no CUI on the equipment, sanitizing or destroying the equipment, or retaining the equipment within the facility.

Determination statements · 800-171A Rev. 3

  1. 03.07.04.a[01] the use of system maintenance tools is approved.
  2. 03.07.04.a[02] the use of system maintenance tools is controlled.
  3. 03.07.04.a[03] the use of system maintenance tools is monitored.
  4. 03.07.04.b media with diagnostic and test programs are checked for malicious code before the media are used in the system.
  5. 03.07.04.c the removal of system maintenance equipment containing CUI is prevented by verifying that there is no CUI on the equipment, sanitizing or destroying the equipment, or retaining the equipment within the facility.

Draws on Rev. 2 3.7.2, 3.7.4.

Left: NIST SP 800-171 Rev. 2 and 800-171A, verbatim. Right: NIST SP 800-171 Rev. 3 and 800-171A Rev. 3, verbatim, with organization-defined blanks highlighted.

Word by word

The Rev. 2 requirement compared with its Rev. 3 successor. A mechanical comparison of the two verbatim texts, not an interpretation.

removed in Rev. 3 added in Rev. 3

Rev. 2 3.7.4 → Rev. 3 03.07.04 Maintenance Tools

Approve, control, and monitor the use of system maintenance tools. Check media containing with diagnostic and test programs for malicious code before the media are it is used in organizational systems. the system. Prevent the removal of system maintenance equipment containing CUI by verifying that there is no CUI on the equipment, sanitizing or destroying the equipment, or retaining the equipment within the facility.

12 words kept, 6 removed, 46 added. Rev. 3 statement labels omitted for the comparison.

What NIST says changed

  • New security requirement title
  • Aligned with SP 800-53, Rev 5 to provide more comprehensive detail on and foundational tasks for maintenance tools
  • Includes withdrawn requirement: 03.07.02

NIST, SP 800-171 Rev. 2 to Rev. 3 change analysis, class “Significant change”. At adoption, Bedrock files this under “Rework”.

NIST's Rev. 3 discussion for 03.07.04

Approving, controlling, monitoring, and reviewing maintenance tools address security-related issues associated with the tools that are used for diagnostic and repair actions on the system. Maintenance tools can include hardware and software diagnostic and test equipment as well as packet sniffers. The tools may be pre-installed, brought in with maintenance personnel on media, cloud-based, or downloaded from a website. Diagnostic and test programs are potential vehicles for transporting malicious code into the system, either intentionally or unintentionally. Examples of media inspection include checking the cryptographic hash or digital signatures of diagnostic and test programs and media. If organizations inspect media that contain diagnostic and test programs and determine that the media also contain malicious code, the incident is handled consistent with incident handling policies and procedures. A periodic review of system maintenance tools can result in the withdrawal of approval for outdated, unsupported, irrelevant, or no-longer-used tools. Maintenance tools do not address the hardware and software components that support maintenance and are considered a part of the system.

What this means for you now

Nothing changes in what you are assessed against until a class deviation or a published rule adopts Rev. 3. Keep meeting 3.7.4 as written in Rev. 2.

Bedrock CMMC shows this same comparison against your own package, with your current status on the Rev. 2 side, so the day adoption lands the migration is a review, not a rewrite.

Back to the Rev. 2 vs Rev. 3 overview

Where this page's facts come from
Rev. 2 text and objectives
bedrock-cmmc-api@89b8e8e:migrations/004_reference_requirements.sql#Requirement.basicRequirement@rev2; bedrock-cmmc-api@89b8e8e:migrations/005_reference_objectives.sql#AssessmentObjective.description@rev2
Mapping and change class
bedrock-cmmc-api@89b8e8e:docs/reference/nist-800-171-rev3/normalized/r2_r3_transition_map.json#r2_to_r3
Rev. 3 03.07.04
bedrock-cmmc-api@89b8e8e:docs/reference/nist-800-171-rev3/normalized/rev3.json#requirements[]